{"id":21,"date":"2023-08-03T13:42:18","date_gmt":"2023-08-03T05:42:18","guid":{"rendered":"https:\/\/anchor-filter.com\/?page_id=21"},"modified":"2026-11-25T17:00:30","modified_gmt":"2026-11-25T09:00:30","slug":"qa","status":"publish","type":"page","link":"https:\/\/anchor-filter.com\/it\/qa\/","title":{"rendered":"Domande e risposte"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"21\" class=\"elementor elementor-21\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4df92c2 e-flex e-con-boxed e-con e-parent\" data-id=\"4df92c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ff4845 elementor-widget elementor-widget-heading\" data-id=\"1ff4845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Ceramic Filter Cleaning and Maintenance FAQ<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-86f2f04 e-flex e-con-boxed e-con e-parent\" data-id=\"86f2f04\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8591888 elementor-widget elementor-widget-text-editor\" data-id=\"8591888\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This FAQ explains ceramic filter cleaning, pulse-jet operation, temperature limits, service life and routine maintenance. It also clarifies how to clean filter media without confusing rigid ceramic tubes with disposable fabric media.<\/p>\n<h2 style=\"text-align: center\"><strong>Characteristics of the Ceramic Fiber Filter\u00a0<\/strong><\/h2><p><strong>Cleaning method<\/strong><strong>\uff1a<\/strong><\/p><p>Its main substrates are alumina and silica.<\/p><p><strong>Operating temperature<\/strong><strong>\uff1a<\/strong><\/p><p>Its continuous operating temperature is up to 600\u2103, with a maximum of 1000\u2103, when only dedusting is considered. For catalytic ceramic fiber filter, the recommended operating temperature is 170\u2013300\u2103 (optimum 220\u2013260\u2103; the low-temperature catalyst reaches 90% DeNOx at 200\u2103 and 98% at 280\u2103).<\/p><p><strong>Corrosion resistance<\/strong><strong>\uff1a<\/strong><\/p><p>Resistant to acid and alkali corrosion( except for super acid and super alkali such as HF, H\u2083PO4, Na\u2082O, K\u2082O when no alkali agent is added)<\/p><p><strong>Non-combustible<\/strong><strong>\uff1a<\/strong><\/p><p>It can contact with the fire directly and it is non-combustible.<\/p><p><strong>Physical strength<\/strong><strong>\uff1a<\/strong><\/p><p>Unlike the traditional bag filter, the ceramic fiber filter can maintain high physical strength at room temperature or high temperature without keel supporting.<\/p><p><strong>Physical structure<\/strong><strong>\uff1a<\/strong><\/p><p>It is made of ceramic fiber to be porous structure, and its wall thickness is 20 mm (standard \u03c6150 \u00d7 \u03c6110 \u00d7 3,000 mm element).<\/p><p><strong>Filtration velocity<\/strong><strong>\uff1a<\/strong><\/p><p>Generally set from 2cm\/s to 5cm\/s, which is far quicker than the filtration velocity of the bag filter. And it can be adjusted according to the actual working conditions.<\/p><p><strong>Filter resistance<\/strong><strong>\uff1a<\/strong><\/p><p>The clean filter resistance is about 350 Pa at 1 m\/min face velocity (no dust).<\/p><p><strong>System resistance<\/strong><strong>\uff1a<\/strong><\/p><p>The resistance of the whole dedusting system is generally 900\u20131,500 Pa.<\/p><p><strong>Filtration accuracy<\/strong><strong>\uff1a<\/strong><\/p><p>It can filter dust larger than 1 micron. For dust smaller than 1 micron, the dedusting effect is also very good if special reagents are added.<\/p><p><strong>Dedusting efficiency<\/strong><strong>\uff1a<\/strong><\/p><p>&gt;99.99%.<\/p><p><strong>Service life<\/strong><strong>\uff1a<\/strong><\/p><p>The ceramic fiber filter normally lasts more than 5 years, and is covered by a 5-year written warranty.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8dae5fe e-flex e-con-boxed e-con e-parent\" data-id=\"8dae5fe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-34171fd elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"34171fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7c75599 e-flex e-con-boxed e-con e-parent\" data-id=\"7c75599\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2cbdff0 elementor-widget elementor-widget-text-editor\" data-id=\"2cbdff0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 style=\"text-align: center\"><strong>How to Clean Filter Media and Ceramic Filter Tubes<\/strong><\/h2><p><strong>Cleaning method:<\/strong><\/p><p>Clean with pulsed compressed gas backflushing<\/p><p><strong>Backflush pressure:<\/strong><\/p><p>Generally, the pressure used is between 0.4mpa and 0.7mpa, which will be determined according to the parameters of the dusty gas and the specifications of the filter.<\/p><p><strong>Backflush time:<\/strong><\/p><p>The backflush process lasts only 0.15 seconds.<\/p><p><strong>Backflush cycle:<\/strong><\/p><p>The backflush cycle can be set up based on the pressure difference. When the pressure sensor reaches the set parameters, the backflush process start.<\/p><p><strong>Backflush Air Volume:<\/strong><\/p><p>Generally, the amount of compressed gas needed for each filter is the amount of the filter&#8217;s volume.<\/p><p><strong>Backflush design:<\/strong><\/p><p>Each backflush tube can generally be used to blow 18 to 20 small diameter filters , or 8 to 10 large diameter filters. The system structure could be designed according to this.<\/p><p><strong>No expansion of bags:<\/strong><\/p><p>Unlike the traditional bag filter, the ceramic fiber filter itself is a rigid structure. The backflush cleaning process will not expand nor deform the filter.<\/p><p><strong>No raised dust:<\/strong><\/p><p>During the backflush process, the dust cake fall off from the ceramic fiber filter without secondary raised dust caused, while bag filter will cause secondary raised dust.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d28c68d e-flex e-con-boxed e-con e-parent\" data-id=\"d28c68d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5f383fc elementor-widget elementor-widget-text-editor\" data-id=\"5f383fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently Asked Questions<\/h2><h3>What is the maximum operating temperature of your ceramic fiber filters?<\/h3><p>The continuous operating temperature is up to 600\u00b0C, with a maximum of 1000\u00b0C, when only dedusting is considered. For catalytic ceramic fiber filters, the recommended operating temperature is 170\u2013300\u00b0C (optimum 220\u2013260\u00b0C; the low-temperature catalyst reaches 90% DeNOx at 200\u00b0C and 98% at 280\u00b0C).<\/p><h3>What is the dust removal efficiency?<\/h3><p>Dust removal efficiency is &gt;99.99%. The filter captures dust larger than 1 micron, and dust smaller than 1 micron can also be removed very well when special reagents are added.<\/p><h3>What is the service life of a ceramic fiber filter?<\/h3><p>Ceramic fiber filters normally last more than 5 years, and each element is covered by a 5-year written warranty.<\/p><h3>Which industries are your filters suitable for?<\/h3><p>They are suitable for glass furnaces, cement kilns, coking plants, thermal power plants, waste incinerators, metallurgical smelting furnaces and biomass boilers.<\/p><h3>What are the filtration velocity and system resistance?<\/h3><p>Filtration velocity is generally set at or below 1.5 m\/min. Filter resistance is 350 Pa at 1 m\/min face velocity (clean, no dust), and the whole dedusting system resistance is generally 900\u20131,500 Pa.<\/p><h3>How are the ceramic fiber filters cleaned?<\/h3><p>They are cleaned with pulsed compressed gas backflushing at a pressure of 0.4 MPa to 0.7 MPa. Each backflush lasts about 0.15 seconds and is triggered by pressure difference.<\/p><h3>Do the filters resist acid and alkali corrosion?<\/h3><p>Yes, they are resistant to acid and alkali corrosion, except for super acid and super alkali such as HF, H3PO4, Na2O and K2O when no alkali agent is added.<\/p><h3>What is the difference between non-catalyst and catalytic ceramic fiber filters?<\/h3><p>Non-catalyst filters are used for dedusting only. Catalytic filters also remove SOx, NOx, HCl and dioxins with desulfurization and denitrification efficiency up to 95%, and are recommended at 170\u2013300\u00b0C (optimum 220\u2013260\u00b0C).<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c13cf37 elementor-widget elementor-widget-html\" data-id=\"c13cf37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"@id\": \"https:\/\/anchor-filter.com\/qa\/#faqpage\", \"url\": \"https:\/\/anchor-filter.com\/qa\/\", \"name\": \"Ceramic Filter Cleaning and Maintenance FAQ\", \"description\": \"Frequently asked questions about ceramic fiber filter tubes: operating temperature, dust removal efficiency, service life, applicable industries, filtration velocity, cleaning method, acid\/alkali resistance and the difference between non-catalyst and catalytic filters.\", \"inLanguage\": \"en-US\", \"isPartOf\": {\"@id\": \"https:\/\/anchor-filter.com\/#website\"}, \"about\": [{\"@type\": \"Thing\", \"name\": \"Ceramic fiber filter\"}, {\"@type\": \"Thing\", \"name\": \"High-temperature flue gas filtration\"}, {\"@type\": \"Thing\", \"name\": \"Industrial dedusting\"}], \"datePublished\": \"2026-09-04\", \"dateModified\": \"2026-09-04\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the maximum operating temperature of your ceramic fiber filters?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The continuous operating temperature is up to 600\u00b0C, with a maximum of 1000\u00b0C, when only dedusting is considered. For catalytic ceramic fiber filters, the recommended operating temperature is 170\u2013300\u00b0C (optimum 220\u2013260\u00b0C; the low-temperature catalyst reaches 90% DeNOx at 200\u00b0C and 98% at 280\u00b0C).\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}, {\"@type\": \"Question\", \"name\": \"What is the dust removal efficiency?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Dust removal efficiency is >99.99%. The filter captures dust larger than 1 micron, and dust smaller than 1 micron can also be removed very well when special reagents are added.\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}, {\"@type\": \"Question\", \"name\": \"What is the service life of a ceramic fiber filter?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Ceramic fiber filters normally last more than 5 years, and each element is covered by a 5-year written warranty.\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}, {\"@type\": \"Question\", \"name\": \"Which industries are your filters suitable for?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"They are suitable for glass furnaces, cement kilns, coking plants, thermal power plants, waste incinerators, metallurgical smelting furnaces and biomass boilers.\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}, {\"@type\": \"Question\", \"name\": \"What is the filtration velocity and system resistance?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Filtration velocity is generally set at or below 1.5 m\/min. Filter resistance is 350 Pa at 1 m\/min face velocity (clean, no dust), and the whole dedusting system resistance is generally 900\u20131,500 Pa.\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}, {\"@type\": \"Question\", \"name\": \"How are the ceramic fiber filters cleaned?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"They are cleaned with pulsed compressed gas backflushing at a pressure of 0.4 MPa to 0.7 MPa. Each backflush lasts about 0.15 seconds and is triggered by pressure difference.\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}, {\"@type\": \"Question\", \"name\": \"Do the filters resist acid and alkali corrosion?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, they are resistant to acid and alkali corrosion, except for super acid and super alkali such as HF, H3PO4, Na2O and K2O when no alkali agent is added.\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between non-catalyst and catalytic ceramic fiber filters?\", \"about\": {\"@type\": \"Product\", \"name\": \"Ceramic fiber filter\"}, \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Non-catalyst filters are used for dedusting only. Catalytic filters also remove SOx, NOx, HCl and dioxins with desulfurization and denitrification efficiency up to 95%, and are recommended at 170\u2013300\u00b0C (optimum 220\u2013260\u00b0C).\", \"author\": {\"@type\": \"Organization\", \"name\": \"Guangzhou Anchor Technology Co., Ltd.\", \"@id\": \"https:\/\/anchor-filter.com\/#organization\", \"url\": \"https:\/\/anchor-filter.com\/\"}, \"dateCreated\": \"2026-09-04\"}}]}<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e1a5346 e-flex e-con-boxed e-con e-parent\" data-id=\"e1a5346\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1853d1f elementor-widget elementor-widget-html\" data-id=\"1853d1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/anchor-filter.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Q&A\",\"item\":\"https:\/\/anchor-filter.com\/qa\/\"}]}<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-09756ba e-flex e-con-boxed e-con e-parent\" data-id=\"09756ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-59ad20a elementor-widget elementor-widget-html\" data-id=\"59ad20a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"max-width:1140px;margin-left:auto;margin-right:auto;box-sizing:border-box;padding-left:15px;padding-right:15px;\"><div class=\"an-related\" style=\"border-top:1px solid #E5E7EB;margin:32px 0 0;padding:16px 0 0;\"><p><strong>Related guides:<\/strong> <a href=\"https:\/\/anchor-filter.com\/pre-coating-ceramic-filter-tubes\/\">pre-coating<\/a><\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0daf171 e-flex e-con-boxed e-con e-parent\" data-id=\"0daf171\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a92f808 elementor-widget elementor-widget-html\" data-id=\"a92f808\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"max-width:1140px;margin-left:auto;margin-right:auto;box-sizing:border-box;padding-left:15px;padding-right:15px;\"><div class=\"an-cta\" style=\"background:#EFF6FF;border:1px solid #BFDBFE;border-radius:8px;padding:18px 22px;margin:28px 0;\"><strong>Need a hot gas filtration solution?<\/strong> Tell us your gas temperature, dust load and flow rate \u2014 our engineers will reply with a sizing suggestion. <a href=\"https:\/\/anchor-filter.com\/contact\/\">Contact us<\/a>: allan.lun@anchorgd.com<\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dcc1224 e-flex e-con-boxed e-con e-parent\" data-id=\"dcc1224\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d821362 elementor-widget elementor-widget-html\" data-id=\"d821362\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the maximum operating temperature of your ceramic fiber filters?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The continuous operating temperature is up to 600\\u00b0C, with a maximum of 1000\\u00b0C, when only dedusting is considered. For catalytic ceramic fiber filters, the recommended operating temperature is 170\\u2013300\\u00b0C (optimum 220\\u2013260\\u00b0C; the low-temperature catalyst reaches 90% DeNOx at 200\\u00b0C and 98% at 280\\u00b0C).\"}},{\"@type\":\"Question\",\"name\":\"What is the dust removal efficiency?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Dust removal efficiency is &gt;99.99%. The filter captures dust larger than 1 micron, and dust smaller than 1 micron can also be removed very well when special reagents are added.\"}},{\"@type\":\"Question\",\"name\":\"What is the service life of a ceramic fiber filter?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ceramic fiber filters normally last more than 5 years, and each element is covered by a 5-year written warranty.\"}},{\"@type\":\"Question\",\"name\":\"Which industries are your filters suitable for?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"They are suitable for glass furnaces, cement kilns, coking plants, thermal power plants, waste incinerators, metallurgical smelting furnaces and biomass boilers.\"}},{\"@type\":\"Question\",\"name\":\"What are the filtration velocity and system resistance?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Filtration velocity is generally set at or below 1.5 m\/min. Filter resistance is 350 Pa at 1 m\/min face velocity (clean, no dust), and the whole dedusting system resistance is generally 900\\u20131,500 Pa.\"}},{\"@type\":\"Question\",\"name\":\"How are the ceramic fiber filters cleaned?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"They are cleaned with pulsed compressed gas backflushing at a pressure of 0.4 MPa to 0.7 MPa. Each backflush lasts about 0.15 seconds and is triggered by pressure difference.\"}},{\"@type\":\"Question\",\"name\":\"Do the filters resist acid and alkali corrosion?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, they are resistant to acid and alkali corrosion, except for super acid and super alkali such as HF, H3PO4, Na2O and K2O when no alkali agent is added.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between non-catalyst and catalytic ceramic fiber filters?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Non-catalyst filters are used for dedusting only. Catalytic filters also remove SOx, NOx, HCl and dioxins with desulfurization and denitrification efficiency up to 95%, and are recommended at 170\\u2013300\\u00b0C (optimum 220\\u2013260\\u00b0C).\"}}]}<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5e5caca e-flex e-con-boxed e-con e-parent\" data-id=\"5e5caca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef1b7c4 elementor-widget elementor-widget-html\" data-id=\"ef1b7c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"max-width:1140px;margin-left:auto;margin-right:auto;box-sizing:border-box;padding-left:15px;padding-right:15px;\"><div class=\"an-related\" style=\"border-top:1px solid #E5E7EB;margin:32px 0 0;padding:16px 0 0;\"><p><strong>Related reading:<\/strong> <a href=\"https:\/\/anchor-filter.com\/catalytic-ceramic-filter-vs-scr\/\">catalytic ceramic filter vs SCR: capex, opex and footprint<\/a> &middot; <a href=\"https:\/\/anchor-filter.com\/dioxin-removal-waste-incinerator\/\">dioxin removal for waste incinerators<\/a> &middot; <a href=\"https:\/\/anchor-filter.com\/low-temperature-denox-catalytic-ceramic-filter\/\">low-temperature DeNOx at 170\u2013300 \u00b0C<\/a><\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>FAQ sui filtri in fibra ceramica, risposte del fornitore specializzato: temperatura di esercizio, efficienza di rimozione della polvere, durata, installazione e manutenzione.<\/p>","protected":false},"author":1,"featured_media":233,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-21","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ceramic Filter Cleaning &amp; Maintenance FAQ | Anchor-Filter<\/title>\n<meta name=\"description\" content=\"Get answers about ceramic filter cleaning, pulse-jet operation, temperature limits, efficiency, service life and how to clean filter media safely.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/anchor-filter.com\/it\/qa\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ceramic Filter Cleaning &amp; Maintenance FAQ | Anchor-Filter\" \/>\n<meta property=\"og:description\" content=\"Get answers about ceramic filter cleaning, pulse-jet operation, temperature limits, efficiency, service life and how to clean filter media safely.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/anchor-filter.com\/it\/qa\/\" \/>\n<meta property=\"og:site_name\" content=\"Anchor-Filter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-25T09:00:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/anchor-filter.com\/wp-content\/uploads\/2023\/08\/filter-pipe-image.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/\",\"url\":\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/\",\"name\":\"Ceramic Filter Cleaning & Maintenance FAQ | Anchor-Filter\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/filter-pipe-image.jpg\",\"datePublished\":\"2023-08-03T05:42:18+00:00\",\"dateModified\":\"2026-11-25T09:00:30+00:00\",\"description\":\"Get answers about ceramic filter cleaning, pulse-jet operation, temperature limits, efficiency, service life and how to clean filter media safely.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/#primaryimage\",\"url\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/filter-pipe-image.jpg\",\"contentUrl\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/filter-pipe-image.jpg\",\"width\":1200,\"height\":600,\"caption\":\"Ceramic fiber filter tube for high-temperature gas filtration\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/qa\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/anchor-filter.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Q&#038;A\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/#website\",\"url\":\"https:\\\/\\\/anchor-filter.com\\\/\",\"name\":\"Anchor-Filter\",\"description\":\"Anchor-Filter supplies ceramic fiber filter tubes and candle elements for high-temperature flue gas dedusting, desulfurization and denitrification.\",\"publisher\":{\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/anchor-filter.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/#organization\",\"name\":\"Guangzhou Anchor Technology Co., Ltd.\",\"url\":\"https:\\\/\\\/anchor-filter.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/anchor-filter-logo.jpg\",\"contentUrl\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/anchor-filter-logo.jpg\",\"width\":1151,\"height\":556,\"caption\":\"Guangzhou Anchor Technology Co., Ltd.\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/#\\\/schema\\\/person\\\/77b479f4ce2e11c82e01a1dbe9d05907\",\"name\":\"Anchor-Filter Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/anchor-filter-team-avatar.png\",\"url\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/anchor-filter-team-avatar.png\",\"contentUrl\":\"https:\\\/\\\/anchor-filter.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/anchor-filter-team-avatar.png\",\"caption\":\"Anchor-Filter Team\"},\"description\":\"Guangzhou Anchor Technology Co., Ltd. \u2014 specialist supplier of ceramic fiber filters for industrial hot gas filtration.\",\"sameAs\":[\"https:\\\/\\\/anchor-filter.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FAQ: pulizia e manutenzione dei filtri ceramici","description":"Risposte su pulizia, getto pulsante, limiti di temperatura, efficienza, durata e pulizia sicura dei mezzi filtranti.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/anchor-filter.com\/it\/qa\/","og_locale":"it_IT","og_type":"article","og_title":"Ceramic Filter Cleaning & Maintenance FAQ | Anchor-Filter","og_description":"Get answers about ceramic filter cleaning, pulse-jet operation, temperature limits, efficiency, service life and how to clean filter media safely.","og_url":"https:\/\/anchor-filter.com\/it\/qa\/","og_site_name":"Anchor-Filter","article_modified_time":"2026-11-25T09:00:30+00:00","og_image":[{"width":1200,"height":600,"url":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2023\/08\/filter-pipe-image.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"4 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/anchor-filter.com\/qa\/","url":"https:\/\/anchor-filter.com\/qa\/","name":"FAQ: pulizia e manutenzione dei filtri ceramici","isPartOf":{"@id":"https:\/\/anchor-filter.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/anchor-filter.com\/qa\/#primaryimage"},"image":{"@id":"https:\/\/anchor-filter.com\/qa\/#primaryimage"},"thumbnailUrl":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2023\/08\/filter-pipe-image.jpg","datePublished":"2023-08-03T05:42:18+00:00","dateModified":"2026-11-25T09:00:30+00:00","description":"Risposte su pulizia, getto pulsante, limiti di temperatura, efficienza, durata e pulizia sicura dei mezzi filtranti.","breadcrumb":{"@id":"https:\/\/anchor-filter.com\/qa\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/anchor-filter.com\/qa\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/anchor-filter.com\/qa\/#primaryimage","url":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2023\/08\/filter-pipe-image.jpg","contentUrl":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2023\/08\/filter-pipe-image.jpg","width":1200,"height":600,"caption":"Ceramic fiber filter tube for high-temperature gas filtration"},{"@type":"BreadcrumbList","@id":"https:\/\/anchor-filter.com\/qa\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/anchor-filter.com\/"},{"@type":"ListItem","position":2,"name":"Q&#038;A"}]},{"@type":"WebSite","@id":"https:\/\/anchor-filter.com\/#website","url":"https:\/\/anchor-filter.com\/","name":"Anchor-Filter","description":"Anchor-Filter fornisce tubi filtranti in fibra ceramica ed elementi a candela per la rimozione delle polveri, desolforazione e denitrificazione di fumi ad alta temperatura.","publisher":{"@id":"https:\/\/anchor-filter.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/anchor-filter.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/anchor-filter.com\/#organization","name":"Guangzhou Anchor Technology Co., Ltd.","url":"https:\/\/anchor-filter.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/anchor-filter.com\/#\/schema\/logo\/image\/","url":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2026\/10\/anchor-filter-logo.jpg","contentUrl":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2026\/10\/anchor-filter-logo.jpg","width":1151,"height":556,"caption":"Guangzhou Anchor Technology Co., Ltd."},"image":{"@id":"https:\/\/anchor-filter.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/anchor-filter.com\/#\/schema\/person\/77b479f4ce2e11c82e01a1dbe9d05907","name":"Anchor-Filter Team","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2026\/10\/anchor-filter-team-avatar.png","url":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2026\/10\/anchor-filter-team-avatar.png","contentUrl":"https:\/\/anchor-filter.com\/wp-content\/uploads\/2026\/10\/anchor-filter-team-avatar.png","caption":"Anchor-Filter Team"},"description":"Guangzhou Anchor Technology Co., Ltd. \u2014 fornitore specializzato di filtri in fibra ceramica per la filtrazione di gas caldi industriali.","sameAs":["https:\/\/anchor-filter.com"]}]}},"_links":{"self":[{"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/pages\/21","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/comments?post=21"}],"version-history":[{"count":1,"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/pages\/21\/revisions"}],"predecessor-version":[{"id":1004,"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/pages\/21\/revisions\/1004"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/media\/233"}],"wp:attachment":[{"href":"https:\/\/anchor-filter.com\/it\/wp-json\/wp\/v2\/media?parent=21"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}